NX-3200/NX-3300

SPECIFICATIONS

GENERAL NX-3200 NX-3300
Frequency Range 136 - 174 MHz  400 - 520 MHz
Max. Channels Per Radio Up to 1000 CH with Option
Number of Channels 512 (64 for no LCD models)
Number of Zones 128 (4 for no LCD models)
Channel Spacing Analog 12.5/15/20/25*/30* kHz
Digital - NXDN 6.25/12.5 kHz
Digital - DMR 12.5 kHz
Power Supply 7.5 V DC ±20%
Battery Life 5-5-90 (FDMA / TDMA)
KNB-55L (1,480 mAh) Approx. 8 hours  Approx. 9.5 hours
KNB-56N (1,400 mAh Approx. 8 hours  Approx. 9.0 hours
KNB-57L (2,000 mAh) Approx. 11 hours Approx. 13.5 hours
Operating Temperature -22ºF to +140ºF (-30ºC to +60ºC)
Frequency Stability ±2.0 ppm ±1.0 ppm
Dimensions (W x H x D) Projections Not Included
Radio Full Keypad Model 2.20 x 4.71 x 1.43 in (56 x 119.6 x 36.4 mm)
KNB-55L (1,480 mAh) 2.20 x 4.71 x 1.43 in (56 x 119.6 x 36.4 mm)
KNB-56N (1,400 mAh) 2.20 x 4.71 x 1.68 in (56 x 119.6 x 42.7 mm)
KNB-57L (2,000 mAh) 2.20 x 4.71 x 1.53 in (56 x 119.6 x 39 mm)
Weight Radio Full Keypad Model 7.8 oz (220 g)
KNB-55L (1,480 mAh) 11.1 oz (315 g)
KNB-56N (1,400 mAh) 14.5 oz (410 g)
KNB-57L (2,000 mAh) 12.0 oz (340 g)
RECEIVER NX-3200 NX-3300
Sensitivity NXDN® 6.25 kHz Digital (3% BER) 0.20 μV
NXDN®12.5 kHz Digital (3% BER) 0.25 μV
DMR 12.5 KHz Digital (5% BER) 0.30 μV
DMR 12.5 KHz Digital (1% BER) 0.45 μV
Analog (12dB SINAD) 0.25 μV
Selectivity Analog @ 12.5 kHz 65 dB
Analog @ 25 kHz 72 dB
Intermodulation 70 dB
Spurious Rejection 70 dB
Audio Distortion 3%
Audio Output Power 500 mW/8Ω (3% Distortion) / 1,000 mW/8Ω (5% Distortion)
TRANSMITTER NX-3200 NX-3300
RF Power Output (High / Mid / Low) 5 W / 4 W / 1 W
Spurious Emission -70 dB
FM Hum & Noise Analog @ 12.5 kHz 40 dB
Analog @ 25kHz 45 dB
Audio Distortion 3%
Digital Protocol ETSI TS 102 361-1, -2, -3
Emission Designator 16K0F3E*, 11K0F3E, 8K30F1E, 8K30F1D, 8K30F7W, 7K60FXD,
7K60FXE, 4K00F1E, 4K00F1D, 4K00F7W, 4K00F2D

* 25 and 30 kHz are not included in the models sold in the USA or US territories. Analog measurements made per TIA603. Specifications are measured according to applicable standards. Specifications shown are typical and subject to change without notice, due to advancements in technology.


APPLICABLE MIL-STD & IP

MIL Standard MIL 810C Methods/
Procedures
MIL 810D Methods/
Procedures
MIL 810E Methods/
Procedures
MIL 810F  Methods/
Procedures
MIL 810G 
Methods/
Procedures
Low Pressure 500.1/Procedure I 500.2/Procedure I, II 500.3/Procedure I, II 500.4/Procedure I, II 500.5/Procedure I, II
High Temperature 501.1/Procedure I, II 501.2/Procedure I, II 501.3/Procedure I, II 501.4/Procedure I, II 501.5/Procedure I, II
Low Temperature 502.1/Procedure I 502.2/Procedure I, II 502.3/Procedure I, II 502.4/Procedure I, II 502.5/Procedure I, II
Temperature Shock 503.1/Procedure I 503.2/Procedure I 503.3/Procedure I 503.4/Procedure I, II 503.5/Procedure I
Solar Radiation 505.1/Procedure I 505.2/Procedure I 505.3/Procedure I 505.4/Procedure I 505.5/Procedure I
Rain 506.1/Procedure I, II 506.2/Procedure I, II 506.3/Procedure I, II 506.4/Procedure I, III 506.5/Procedure I, III
Humidity 507.1/Procedure I, II 507.2/Procedure II, III 507.3/Procedure II, III 507.4 507.5/Procedure II
Salt Fog 509.1/Procedure I 509.2/Procedure I 509.3/Procedure I 509.4 509.5
Dust 510.1/Procedure I 510.2/Procedure I 510.3/Procedure I 510.4/Procedure I, III 510.5/Procedure I
Vibration 514.2/Procedure VIII, X 514.3/Procedure I 514.4/Procedure I 514.5/Procedure I 514.6/Procedure I
Shock 516.2/Procedure I, II, V 516.3/Procedure I, IV 516.4/Procedure I, IV 516.5/Procedure I, IV 516.6/Procedure I, IV
International Protection Standard
Dust & Water Protection IP54/55/67